Technical specifications
Temperature range
0°C to +60°C
Max. current consumption by 24V
<500mA @ 25°C (allrelays and inputs activated)
Max. input current E2/4
2mA @ 25°C / Input
Max. input current E1/3/5/6/7/8
10mA @ 25°C / Input
Max. current KH11-KH16; KH41-KH42
8A/250V AC / Relay
Max. input current 230V inputs (Safety line, contactor monitoring)
10mA @ 25°C, 230VAC, 50Hz / Input
Mechanical dimensions
Length: 292mm
Width: 183mm
Height: ca. 40mm
Width: 183mm
Height: ca. 40mm
Order information
HSE Version 1.5Characteristics
- Highly integrated Infineon – Microcontroller with internal Flash memory
- Modern FRAM Technology for storing events, faults and other data
- Integrated battery charging circuit
- Operation of HSE with battery power supply possible
- battery buffered 24V power supply output
- Integrated real-time clock
- 2 opto-isolated CAN-Bus systems (conterl bus, shaft bus)
- 1 RS232 interface
- 6 opto-isolated digital inputs, low active
- 2 opto-isolated inputs for PTC; also usable as digital inputs (low active)
- 4 TÜV-certified, EN81 compliant safety circuit monitoring inputs 110V/230V AC, 50/60Hz (opto-isolated)
- 1 input 110V/230V AC, 50/60 Hz (opto-isolated)
- 2 EEPROM memories for parameters (32kByte each; in socket)
- 4-layer PCB with internal power layers
- JTAG interface for software update
- Software update by RS232 / USB / Ethernet / Modem / GSM possible
- 8 freely programmable Relays
- integrated alarm call relay
- various LED status indicators
- Keypad with 14 keys
- LCD – Display 4 lines / 16 characters
- Interface for incremental encoder
- onboard-connector for modem module / Ethernet module / GSM module
- Integrated temperature sensor