Handheld terminal DSE Version 1.1

Technical specifications

Temperature range
0°C to +60°C
Max. Power consumption by 24V
70mA @ 25°C
Mechanical dimensions
Width: 90mm
Height: 200mm
Depth: 35mm
Cable length
2m
Handheld terminal DSE Version 1.1
Handheld termina DSE Version 1.1, Adaptor cable for FVE 1.1

Order information

Handheld terminal Version 1.1

Adapter cable for handheld terminal for connector on FVE Version 1.1:
Adapter cable handheld terminal 2m

Characteristics

  •  Service tool for lift controller MLC-8000
  • can be connected to any connector on control bus (CAN bus 1) or shaft bus (CAN bus 2)
  • Complete control of HSE and lift controller from any place
  • handheld terminal connectors are available by default on HSE, FVE, TVE and LCD-057
  • Plug and unplug while power is on even if lift is running
  • Keypad with 14 keys
  • LCD display 16*4 characters with backlight
  • CAN bus data rate switchable between 125 kBaud (default) and 250 kBaud by pressing key ‘0’ directly after power on (actual value is displayed on LCD of handheld terminal)